Skip to content
Kanato Masayoshi
Back to profile & projects

Medical imaging AI · Uncertainty

Estimating retinal non-perfusion from fundus images

We studied AI models for identifying areas of the retina with no blood flow (non-perfusion) from fundus images. We extended the work from fluorescein angiography to color fundus photographs, also using synthetic angiography images created with generative AI to evaluate segmentation accuracy and uncertainty in model predictions.

Figure 1 compares three models using FA, color fundus images, and GAN-generated synthetic FA. The color model achieved comparable accuracy with less stable performance; synthetic FA had mixed effects on accuracy but reduced uncertainty.
Study overview

Overview of the 2024 study. Three models using fluorescein angiography (FA), color fundus images, or color fundus images with synthetic FA created with generative AI were compared to examine non-perfusion area detection and the added value of synthetic images.

Background

The extent of retinal non-perfusion is important in assessing retinal vein occlusion. Fluorescein angiography, used to assess these areas, requires an injected contrast agent. We investigated whether AI could segment non-perfusion areas and whether they could also be estimated from color fundus photographs, which do not require a contrast agent.

Approach

In our 2022 study, we developed and evaluated deep learning models to segment non-perfusion areas in angiography images. We also used Monte Carlo dropout (MC dropout) to identify areas where predictions were uncertain. Showing this uncertainty on the image makes it easier to distinguish areas where the prediction is more reliable from those that need careful review by a physician.

In 2024, we extended the work to color fundus photographs and synthetic angiography images created from them with generative AI.

Current status

Color fundus photographs showed promise for estimating non-perfusion, but prediction stability remained a challenge. Adding synthetic angiography images improved uncertainty estimation. These findings do not establish that the approach can replace fluorescein angiography.

I reported both studies as first author in peer-reviewed journals. Both were retrospective image analysis studies, and further validation is needed to establish their clinical usefulness.

Figure 5 compares three cases: color fundus, real and synthetic angiography, annotations, predicted non-perfusion areas, and uncertainty maps for three models, with Dice scores above.
Predicted regions and uncertainty

Three cases from the 2024 study comparing predicted regions and uncertainty across color fundus, angiography, and synthetic angiography inputs. The examples include cases where synthetic angiography was helpful and cases where it failed to preserve abnormal findings.

Related publications

Discuss related research or development